How to Artificially Inseminate Gilts and Sows Post Cervically

0 / 5. 0

Source:

https://www.youtube.com/watch?v=v3UG6hhkamM

Duration: 

00:09:45

Year of Production: 

2018

Source/Author: 

NeogenCorp
»As a breeding technician, you are only good as the tools you use and how accurately you detect sows in heat. Conventional artificial insemination, or AI, has been a heavily utilized tool since the 1990s to make use of new, superior genetics at a potentially lower cost than natural-service systems, reduce the risk of disease transmission, and improve conception rates. However, since the 2000s, a new tool has been developing. Post cervical artificial insemination, or PCAI, can be used to continue to lower semen dose, improve genetic potential, and improve conception rates. PCAI is an insemination tool that allows for semen to be deposited into the uterus, which is closer to the location of the eggs. To do this, a special catheter is used that has two pieces, an outer rod that is like a conventional AI catheter, and a smaller diameter inner rod, that can pass through the cervix and into the uterus. For more information on NEOGEN®‘s extensive line of reproductive products, please visit NEOGEN.com.«

Being a good source of protein, the quality and quantity of pigs produced on farm is determined by the type of technology used.

The post cervical artificial insemination is where sows are bred by depositing semen into uterus and a catheter is used of small diameter which easily pass through cervix to the uterus. PCAI is used to facilitate lower dosage of semen for insemination and faster insemination times. This allows to inseminate more females which saves money for insemination and saves labour time.

Insemination procedure

First in PCAI, boer is not required during insemination process which calls up for the gentle squeeze of semen through catheter to speed up the process. Boer is only needed for heating which relaxes cervix in 15 minutes after checking and the ideal time for PCAI is between 15-40 minutes after the checkup.

In addition, prepare equipment for PCAI as pink catheters are for sow and green ones for gilts, clean and dry paper towel, gloves and lubricants. Heat check is done as a sow on standing heat stands firm in one place, vulva is reddened and swollen with mucus out of it.

Wait for 15-20 minutes for cervix to relax, collect semen from cooler, double check temperatures, clean the vulva of sow or gilt by removing any manure using clean dry paper towel and prepare PCAI catheter for insemination. Open the package gently to remove catheter and insert catheter at 45 degree angle, straighten it to cervix and gently turn catheter counter clockwise to ensure it is locked in.

Furthermore, using temperature control semen, attach to end of catheter and deposit semen however, when using semen bag, attach dosage gun tip to the catheter and squeeze 1 dose slowly into catheter. Hold bag of dose up at higher and to prevent back flow of semen.

Remove catheter after insemination and inspect it for any leakage or blood and finally record completion according to farm protocol and train employees as well for good result on farm.

Sequence from Sequence to Description
00:0001:11PCAI is where sows are bred by deposting semen in the uterus.
01:1201:45A catheter is used of small diameter which easily pass through cervix to uterus.
01:4601:54In PCAI, boer is not required during insemination process.
01:5502:29Gently squeeze the semen through catheter to speedup process.
02:3002:44Boer is needed for heat checking which relaxes cervix in 15 minutes after heat checking.
02:4502:51The ideal time for PCAI is between 15 and 40 minutes after checking.
02:5203:13For PCAI, prepare equipments as pink catheters are for sows and green for gilts.
03:1404:03Others include clean dry paper towel, gloves, lubricant.
04:0404:17Heat check is done as a sow on standing heat stands firm in one place.
04:1804:21The vulva is reddened and swollen with mucus out of it.
04:2204:29Wait for 15-20 minutes for cervix to relax.
04:3004:44Collect semen from cooler and double check temperatures.
04:4504:58Clean the vulva of sow or gilt by removing any manure using clean dry paper towel.
04:5905:20Prepare PCAI catheter for insemination.
05:2106:23Apply lubricant on catheter and insert it into the sow.
06:2406:59Using temperature control semen, attach to end of catheter and deposit semen.
07:0008:03Remove catheter after insemination and inspect it for any leakage of blood.
08:0408:36Record completion according to farm protocol.
08:3709:12Train employees for good results on farm.
09:1309:45Summary

View external video

By clicking the following link or play button you will leave the FO Video Library and switch to an external website! We would like to see you again, so don’t forget to come back!

Leave a short comment

Leave a Reply

Your email address will not be published. Required fields are marked *